19
Wrong Setting Because you add “...” After .A0 17$
The 0.A17$ is a FIXED parameter for setup entering. It is
an unchangeable parameter. Never add, delete or
rearrange data from the FIRST row.
Only the settings that are different from the default values will be dumped.
The settings can be dumped to a PC or terminal only if that PC or terminal
matches the type defined by Device Type of the scanner. The previous
example of "Keyboardless Wedge" as Device Type is equivalent-to a
PC/AT interface, so you cannot dump that settings to a system which dose
not support a PC/AT keyboard interface.
The following label dumps the settings to a PC/AT regardless what kind of
device has been chosen on the scanner.
Dump Settings On PC/AT
You can adjust the length of the dumped strings by combining multiple
strings into one or breaking one string into multiple strings. The following
strings have the same effect as the dumped string listed above:
...1800C06D51DJ8080
80A007C005354415254.
You cannot delete any character from or add any character into the strings and
the first three characters ("...") must be present in the first string.
All characters in dumped strings are in upper case. If you see lowercase
characters in dumped strings, change them to upper case.
Scanner Configuration Manager Software
Scanner Configuration Manager is a utility program to users to configure
scanner settings on a computer using the Microsoft Windows based
operating system. Use this program to define the settings and then
download the parameters to the scanner.
Kommentare zu diesen Handbüchern