MS860G WiFi Manual 29
SCANNER CONFIGURATION MANAGER
Bar Code Symbologies, continued
Interleaved 2 of 5
• Enabled toggles the ability for the scanner to read I 2 of 5 on or
off.
Default is “Yes”.
• Code ID is a user-definable identification letter for I 2 of 5,
which is referred to in the “Use Code ID” function on page 25.
Default is
letter “I”.
• Fix Length (by first 3 reads) fixes the length of acceptable
subsequent bar code reads from the first three bar codes read.
Useful as a data verification if all bar codes are of a consistent
length.
Default is “No”.
• Check Digit defines whether or not a check digit (to insure
data accuracy) is calculated, and if so, whether it should be
sent or not.
Default is “Not Calculate”.
• Supress Digit suppresses the output of the first or last bar code
digit.
Default is “Not Suppressed”.
• Minimum Length defines the minimum length the user will
accept for a valid bar code.
Default is “10”.
• Maximum Length defines the maximum length the user will
accept for a valid bar code.
Default is “64”.