Unitech MS860 Bedienungsanleitung Seite 55

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 96
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 54
MS860 WiFi Manual
SCANNER CONFIGURATION MANAGER
Bar Code Symbologies, continued
UPC-A
z
Enabled toggles the ability for the scanner to read UPC-A on or off.
Default is “Yes”.
z
Code ID is a user-definable identification letter for UPC-A, which is
referred to in the “Use Code ID” function on page 45.
Default is letter “A”.
z
Send Leading Digit toggles sending or not sending a leading
(‘start bar code’) digit.
Default is “Send”.
z
Send Check Digit toggles sending or not sending a check digit.
Default is “Send”.
Codabar
z
Enabled toggles the ability for the scanner to read Codabar on or off.
Default is “Yes”.
z
CLSI Format deletes the start and stop sentinels, and outputs the
data with spaces inserted after the 1st, 5th, and 10th characters.
Default is “No”.
z
Check Digit defines whether or not a check digit (to insure data
accuracy) is calculated, and if so, whether it should be sent or not.
Default is “Not Calculate”.
z
Send Start/Stop toggles sending or not sending start/stop sentinels.
Default is “No Send”.
z
Minimum Length defines the minimum length the user will accept
for a valid bar code.
Default is “3”.
z
Maximum Length defines the maximum length the user will accept
for a valid bar code.
Default is “48”.
z
Code ID is a user-definable identification letter for Codabar, which is
referred to in the “Use Code ID” function on page 45.
Default is letter “N”.
53
Seitenansicht 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 95 96

Kommentare zu diesen Handbüchern

Keine Kommentare