Unitech MS350 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Barcodeleser Unitech MS350 herunter. Unitech MS350 User`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 133
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
Installation
The MS350 Wireless Imager is easy to install and use.
Please see the following figure showing the steps to perform
the installation.
* Note: Turn off the host computer before installation.
1. Connect the interface (I/F) cable to the cradle.
2. Connect the power cord to the cradle.
3. Route the I/F cable and power cord through the notch.
4. Connect the I/F cable to the host computer
communication port.
5. Connect the AC adapter to the wall outlet.
6. Place the imager in the cradle and verify the charge
LED is flashing. Charge the battery for at least 8 hours
before the first use.
7. To verify operation, please link the imager with cradle
first (Refer to Wireless Connection in page 5). Point
the imager at the barcode and pull the trigger. The
imager should emit a beep indicating that the barcode
has been scanned and transmitted to the cradle
successfully.
Seitenansicht 0
1 2 3 4 5 6 ... 132 133

Inhaltsverzeichnis

Seite 1 - Installation

1 Installation The MS350 Wireless Imager is easy to install and use. Please see the following figure showing the steps to perform the installation.

Seite 2 - How To Scan

10 Note: DO NOT touch the PCBA inside the imager when replacing the battery. Improper operation may damage the image

Seite 3 - Troubleshooting

100 Italian Pharmacode (Code 32) Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code l

Seite 4

101 Read Disable Enable 00* 01 Max. code length 00-64 00-64 12* Min. code length 00-64 00-64 09* Truncate leading 0-15 00-15 00*

Seite 5 - Wireless Connection

102 Exit Insert group number selection 00* Leading “A” Disable Enable 00* 01 Code-16K Truncate leading/ending: Refer to Truncate leadi

Seite 6 - Unlinking

103 Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < >*

Seite 7

104 Exit Insert group number selection 00-44 00-ffH 00-44 00*

Seite 8 - Battery Charging

105 PDF-417 Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group

Seite 9 - How to Change the Battery

106 Exit Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15

Seite 10

107 EAN UCC Composite For the coupon extended code application. Coupon extended code is a supplementary barcode that is printed to the right of the

Seite 11

108 Exit *YAK* UCC / EAN128 emulation Disable Enable 00* 01

Seite 12 - Auto Update

109 RSS-14 Read: Format Data Digits (Variable) Checksum1 (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID s

Seite 13 - *$%-1BA03%%*

11 Wireless Features The MS350 Wireless model includes an imager and a cradle. When the imager and cradle are linked togeth

Seite 14 - Deep Sleep Mode

110 Exit Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < R4 >* Inse

Seite 15 - Handcuff Mode (Leash Alarm)

111 RSS-Limited Read: Format Data Digits (Variable) Checksum1 (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code

Seite 16 - Wireless Connectivity

112 Exit Code ID setting 00-ffH ASCII code 00-ffH < RL >* Insert group number selection 00-44 00-44 00* UCC/EAN128 emulation Disable

Seite 17

113 RSS-Expanded Read: Format Data Digits (Variable) Checksum1 (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Cod

Seite 18 - Inquiry Beep Control

114 Exit Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < RX >* Insert group number selection 00-44 00-4

Seite 19 - *$%-5AJ07%%*

115 Micro-PDF Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion grou

Seite 20 - Cradle Beep Loudness Control

116 Exit *XAI* Insert group number selection 00-44 00-44 00* *XAJ* Escape sequence transmit None GLI protocol ECI protocol 00 01 02*

Seite 21 - *$%-5AK07%%*

117 String setting / Transmission (Prefix / Suffix) Prefix / Suffix characters setting: Characters defined as prefix or suffix characters will be tr

Seite 22 - Additional Features

118 Exit Option Bar Code Option Alphanumeric Entry Prefix characters setting None 1-22 characters 00* 00-ffH ASCII code Suffix characters se

Seite 23 - Default setting

119 String setting / Transmission (Preamble/Postamble) Preamble/ Postamble characters: Preamble or Postamble characters will be appended to the data

Seite 24 - Specification

12 Auto Update When this feature is enabled, an imager and its linked cradle can automatically ensure they stay in sync with regard to firmware and

Seite 25

120 Exit Option Bar Code Option Alphanumeric Entry Preamble characters setting 1-22 characters “PREAMBLE”* 00-ffH ASCII code Preamble transm

Seite 26

121 String setting / Transmission (Insert Group Characters) Insert G1/G2/G3/G4 character setting: The imager supports inserting two groups with each

Seite 27 - Indications of MS350

122 5) Repeat the same procedure in Insert G2 characters setting. 6) Scan Exit barcode. 1) Insert data group 1-4 position. Please refer to the speci

Seite 28

123 Option Bar Code Option Alphanumeric Entry Insert G1 characters setting 1-22 characters “GROUP1”* 00-ffH ASCII code Insert G2 characters

Seite 29 - Programming the MS350

124 Exit Insert data group 2 position 00-64 (00: no insertion) 00-64 00* Insert data group 3 position 00-64 (00: no insertion) 00-64 00* Ins

Seite 30 - Finish barcode

125 String setting / Transmission (Others) Code ID position: Upon your usage, the transmitting position of Code ID can be selected to place Before C

Seite 31 - Interface Selection

126 Exit Code ID position Before code data After code data 00* 01 Code ID transmission Disable Proprietary ID AIM ID 00* 01 02 Code length trans

Seite 32 - Keyboard wedge

127 Test Chart (Bar code samples marked with symbol “*” are enabled initially.) CODABAR-PARA CODE-11 PARA CODE-128 PARA * CODE-39 PARA * CODE-

Seite 33

128 PDF-417 * STANDRAD-25 PARA CODE-16K EAN-8 PARA * INDUSTRIAL-25 PARA UPCE PARA * 87549

Seite 34

129 INTERLEAVED-25 PARA * MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA * UK/PLESSEY PARA RSS Micro-PDF *

Seite 35

13 ? Enable firmware auto update only – Allows only firmware updating. ? Disable auto update – No automatic updates will be performed.

Seite 36

130 ASCII Code Table Note: For keyboard wedge only. L H 0 1 0 1 0 Null NUL DLE 1 Up F1 SOH DC1 2 Down F2 STX DC2 3 Left F

Seite 37

131 Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current barcode reading configuration o

Seite 38

132 Exit Query present cradle firmware version Program Firmware version list If you wish to display the cradle a

Seite 39

133 0 1 2 3 4 5 6 7 8 9 A B C Finish F E D

Seite 40

14 Deep Sleep Mode The WIRELESS imager can be placed into Deep Sleep Mode after this programmed duration (since the units ’ last scanning activity

Seite 41

15 Handcuff Mode (Leash Alarm) When enabled, the Leash Alarm will force the imager to sound an alarm for a preprogrammed length of time to notify i

Seite 42 - Pin Assignments

16 Wireless Connectivity The MS350 can be linked to any Bluetooth (BT) enabled device which can accept such a connection with other devices. To imp

Seite 43

17 Wireless Connectivity (continued) User is also allowed to set any four- to six-character PIN code assigned to the target Bluetooth device using

Seite 44

18 Inquiry Beep Control When the cradle is not linked to an imager, the Radio LED will blink amber and the cradle will beep. This beep can be disab

Seite 45

19 ? Inquiry beep every 50 seconds ? Inquiry beep every 60 seconds ? Inquiry beep every 70 seconds *$%-5AJ05%%**$%-5AJ06%%**$%-5AJ0

Seite 46

2 How To Scan 1. The imager must be pointed at slight angle to the barcode so that the light reflected off the barcode can be seen by the imager. D

Seite 47

20 Cradle Beep Loudness Control The beep loudness of cradle can be defined with the following levels. ? Cradle beep off ? Level 1 ? Lev

Seite 48 - Indication

21 ? Level 6 ? Level 7 *$%-5AK06%%**$%-5AK07%%*

Seite 49

22 Additional Features Here list three additional features of MS350 wireless imager for the convenience of use to users. ? Download firmware from

Seite 50

23 Default setting For each barcode shown as below: Code Type Read Enable Checksum Verification Enable Checksum TransmissionEnable Code ID UPC-

Seite 51

24 Specification Unitech MS350 Specification Model MS350 Operational Light Source 630 nm Visible Red LED Optical System 2048 pixel CCD (Charge-

Seite 52 - UCC / EAN 128

25 Depth-head 44 mm Weight Less than 200g (with a battery) Case material ABS (over molded at contact points) Cushion material Double injection C

Seite 53

26 Current – Sleep (Imager) 2 mA Light Level Up to 45000 Lux Shock (Imager) 1.5m drop onto concrete Shock (Cradle) 90cm drop onto concrete Conta

Seite 54

27 Indications of MS350 Imager: Status Green LED Red LED Orange LED Beeper Link established Blink once A special beep Loss link (handcuff mode

Seite 55

28 Cradle: Status Green LED Red LED Orange LED Beeper Inquiry Blink Beeps once a second Connecting Blink Link established ON Ha

Seite 56

29 Programming the MS350 To program the MS350, you must scan a series of programming barcode in the correct order. Fold out the back cover of this ma

Seite 57 - UCC/EAN 128

3 Troubleshooting If the imager can not operate properly, the following checks should be performed: 1. The cradle uses an external power supply an

Seite 58

30 Option Bar Code Option Alphanumeric Entry Interface selection Keyboard Wedge RS-232 Wand emulation USB Keyboard/RS-232 Auto d

Seite 59

31 Exit Interface Selection This cradle comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, and USB interface. In

Seite 60

32 Exit Keyboard wedge As a keyboard interface, the cradle supports most of the popular PCs and IBM terminals. The installation of the wedge is a fa

Seite 61

33 Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need

Seite 62

34 Entry Keyboard layout USA Belgium Danish France Germany Italian Portuguese Spanish Swedish Switzerland UK Latin American Japanese 00* 01 02 03 0

Seite 63

35 Exit only) Alt+Keypad 02 Keyboard wedge Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF”, imager can get Caps Lock status. Power-on s

Seite 64

36 Exit Option Bar Code Option Alphanumeric Entry Caps lock Caps lock”ON” Caps lock”OFF” 00 01* Power-on simulation Disable Enable 00*

Seite 66

38 RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 1116) Xoff: Transmit Off (ASCII

Seite 67 - Code 39

39 Exit Option Bar Code Option Alphanumeric Entry Flow control None RTS/CTS Xon/Xoff ACK/NAK RTS/CTS bracket mode 00* 01 02 03 04 Inter-chara

Seite 68

4 3. Verify the interface cable is securely connected to the cradle. 4. Check that the barcodes are of sufficient quality to be recogniz

Seite 69

40 Exit Option Bar Code Option Alphanumeric Entry Baud rate 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS 00 01 02

Seite 71 - Interleaved 2 of 5

42 Pin Assignments 10-pin AS Series 10-pin RJ-45 Connector Pin RS-232 Keyboard 1 I/F I/F 2 NA NC 3 TXD NC 4 NC CLK / PC 5

Seite 72

43 Keyboard Wedge PS/2 Connector (To Host Side): Pin Mini-DIN 6P Male Mini-DIN 6P Female 1 DATA / PC DATA / KB 2 NC NC 3 GND GND 4

Seite 73 - Industrial 2 of 5

44 Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of imager stops scanning when there

Seite 74

45 Exit Option Bar Code Option Alphanumeric Entry Scanning mode Good-read off Momentary Alternate Timeout off Continue Test only 00 01* 02 0

Seite 75 - Matrix 2 of 5 Eur

46 Scan Global min./max. code length: These are to define the min/ max readable code length of all symbologies. Code length less than min. code leng

Seite 76

47 Exit Option Bar Code Option Alphanumeric Entry Global min. code length 00-99 00-99 04* Global max. code length 00-99 00-99 99* Inverte

Seite 77 - Codabar

48 Indication Power on alert: After power-on the cradle it will generate an alert signal to indicate a successful self -test. LED indication: Aft

Seite 78

49 Exit Option Bar Code Option Alphanumeric Entry Power on alert Disable Enable 00 01* LED indication Disable Enable 00 01* Beeper indicati

Seite 79

5 Wireless Connection Linking the imager with the cradle Follow these instructions to link the two devices: 1. Connect power to the cradle. The ra

Seite 80 - Code-128

50 UPCA Format Leading Zero Data Digits (11 Digits) Check Digit Read: Enable or disable the read function. Check -sum transmission: By setting Enabl

Seite 81

51 Exit Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01* Check-sum transmission Disable Enable 00 01* Truncate leading

Seite 82

52 UPCA Insertion group number selection: The imager offers max. two insertion grou

Seite 83

53 Exit Option Bar Code Option Alphanumeric Entry Insert group number selection 00-44 00-44 00* Supplement digits None 2 digits 5 digits

Seite 85 - Code-93

55 UPCE Read: Format Leading Zero Data Digits (6 Digits) Check Digits Check -sum transmission: By setting Enable, checks sum will be transmitted.

Seite 86

56 Exit Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < E >*

Seite 87

57 UPCE Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Supplement digits: Format Leading Zero Data Dig

Seite 88 - Code-11

58 Exit Supplement digits None 2 digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All 00* 01 02 03 04 05 06 07 Truncation/

Seite 89

59 EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate

Seite 90 - MSI/plessey

6 Unlinking There are three ways to unlink an imager from a cradle: Force imager to disconnect and sleep 1. Scan the “Force imager to di

Seite 91

60 Exit Truncate ending 0-15 00-15 00*

Seite 92 - UK/plessey

61 EAN-13 Code ID setting: Refer to page 51 Insertion group number selection of UPCA. Insertion group number selection: Refer to Insertion group sel

Seite 93

62 Exit Supplement digits None 2 digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All 00* 01 02 03 04 05 06 07 ISBN/ISSN co

Seite 94 - Telepen

63 EAN-8 Read: Format Data Digits (7 Digits) Check Digits Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate lead

Seite 95

64 Exit Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH, 00-ffH < FF >* Insert group number selection 00-44 00-4

Seite 96 - Standard 2 of 5

65 EAN-8 Supplement digits: Format Data Digits (7 Digits) Check Digits Supplement Digits 2 or 5 or UCC/EAN 128 Truncation / Expansion: Refer to Trun

Seite 97

66 Exit 02 Expansion Disable Enable 00* 01

Seite 98

67 Code 39 Read: Format Start “? ” Data Digits ( Variable) Checksum (Optional) End “? ” Check -sum verification: The checksum of Code-39 is optio

Seite 99

68 Exit Check-sum verification Disable Enable 00* 01 Check-sum transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. c

Seite 100

69 Code 39 Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Format: The Full ASCII Code-39 is an enhanc

Seite 101

7 4. Push the “Reset” button on the bottom of cradle – If the cradle is linked with an imager and in range, pushing the “Reset” button (for about 2

Seite 102

70 Exit Format Standard Full ASCII 00* 01 Append Disable Enable 00* 01 Start/end transmission Disable Enable 00* 01

Seite 103

71 Interleaved 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Check -sum verification: The checksum is made as the sum module 10 of

Seite 104

72 Exit Check-sum transmission Disable Enable 00* 01 Max. code leading 00-64 00-64 00* Min. code leading 00-64 00-64 00* Truncate leading

Seite 105 - PDF-417

73 Industrial 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Tru

Seite 106

74 Exit Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < i >* Insert group nu

Seite 107 - EAN UCC Composite

75 Matrix 2 of 5 Eur Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 10 of t

Seite 108

76 Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading

Seite 109

77 Exit Insert group number selection 00* Codabar Read: Format Checksum Verification: The checksum is made as the sum module 16 of the numerica

Seite 110

78 Exit Checksum Verification Disable Enable 00* 01 Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. co

Seite 111

79 Codabar Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Start/End type: The Codabar has four p

Seite 112

8 Battery Charging The imager contains a 1000mAh Lithium-Ion rechargeable battery. A full charged battery will provide up to 15,000 scans over a 12

Seite 113

80 Exit Start/End transmission Disable Enable 00 01* Code-128 Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification:

Seite 114

81 Exit Checksum Transmission Disable Enable 00* 01

Seite 115

82 Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Cod

Seite 116

83 Exit Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code 00-ffH < # >* Insert g

Seite 117 - (Prefix / Suffix)

84 Exit Code-128 ISBT enable: This feature is commonly used in a blood bank for identification. ISBT concatenation timeout: This feature is to setup

Seite 118

85 Exit Code-93 Read: Format Data Digits (Variable) Checksum1 (Optional) Checksum2 (Optional) Checksum Verification: The checksum is made as the s

Seite 119 - (Preamble/Postamble)

86 Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Co

Seite 120 - POSTAMBLE”*

87 Exit Code ID setting 00-ffH ASCII code 00-ffH < & >* Insert group number selection 00-44 00-44 00*

Seite 121 - (Insert Group Characters)

88 Code-11 Read: Format Data Digits (Variable) Checksum1 (Optional) Checksum2 (Optional) Checksum Verification: The checksum is presented as the s

Seite 122

89 Exit Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading

Seite 123

9 How to Change the Battery In case the contained battery inside the imager needs to be replaced, please follow the procedures below:

Seite 124

90 MSI/plessey Read: Format Data Digits (Variable) Checksum1 (Optional) Checksum2 (Optional) Checksum Verification: The MSI/Plessey has one or two

Seite 125 - (Others)

91 Exit 03 Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate lead

Seite 126

92 UK/plessey Read: Format Data Digits (Variable) Checksum1+2 (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum di

Seite 127

93 Exit Checksum Transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading

Seite 128

94 Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the

Seite 129

95 Exit Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-

Seite 130

96 Standard 2 of 5 Read: Format Data Digits (Variable) Checksum1 (Optional) Check -sum verification: The checksum is made as the sum module 10 of

Seite 131 - Parameter Setting List

97 Exit *JAC* Check-sum transmission Disable Enable 00* 01 Max. code length 00-64 00-64 00* Min. code length 00-64 00-64 00* Truncate lea

Seite 132 - *$%-+IC%%*

98 China Post Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncat

Seite 133

99 Exit Min. code length 11* Truncate leading 0-15 00-15 00* Truncate ending 0-15 00-15 00* Code ID setting 00-ffH ASCII code

Kommentare zu diesen Handbüchern

Keine Kommentare